GS 1000 |
GS 2000 |
GS 3000 |
|
Power Rating |
1000W |
2000W |
3000W |
Nominal input Voltage |
120/230VAC |
||
Low Line Disconnect |
85Vac±4%(Normal) or 80Vac±4%(Wide) for 120Vac 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230Vac |
||
Low Line Re-connect |
95Vac±4%(Normal) or 85Vac±4% (Wide) for 120Vac 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230Vac |
||
High Line Disconnect |
136Vac±4%(Normal) or 145Vac±4%(Wide) for 120Vac 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230Vac |
||
Max AC input Voltage |
120Vac for Max150Vac, 230Vac for Max270Vac |
||
Frequency |
50Hz:41-54Hz,60Hz:51-64Hz |
||
Nominal Charge Current |
20A/35A/50A/70A/90A(5 stages adjustable charging current) |
||
Over Charge Protection |
Bat.V>15.5VDCfor 12V battery ; Bat.V>31.0VDC for 24V battery, Bat.VN62.0VDC for 48V battery ; beeps 0.5s every 1s & fault after 60s |
||
Rated Charge Current |
40A |
60A |
60A |
PV Input Voltage range |
12VDC. 25VDC-75VDC for 24VDC. 55-145VDC for 48V |
||
Max.PV open circuit array voltage |
12V for40VDC, 24V for 75VDC, 48V for 145VDC |
||
Charger mode |
MPPT |
||
PV Low Voltage Disconnect |
PVWBat.V |
||
Efficiency |
>97% |
||
Nominal Charger Current |
20A/35A/50A/70A/90A(According to the inverter model), 5 stages adjustable charging current |
||
Over charge Protection |
Bat.V>15.5VDC/31VDC/62VDC,beeps 0.5s every 1s & fault after 60s |
||
Efficiency (Battery Mode ) |
>87% |
||
Efficiency(Line Mode) |
>98% |
||
Nominal DC Input Voltage |
12/24/48VDC |
||
Over-Load Protection |
110%<load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, load>150%, beeps 0.5s every 1 s, and Fault after 20s |
||
Power Saver |
Load<25W(Enabled on "P/S auto"Setting of Remote control) |
||
Protections |
Low battery.over charging,over load,over temp |
||
Indicators |
LED+LCD Display |
||
Operating Temperature Range |
0°C to 40°C |
||
Storage Temperature |
-15°C 〜60°C |
||
Operation humidity |
5% to 95%(non-condensing) |
||
Audible Noise |
60dB max |
||
Dimension(L*W*H) |
480x336x190mm |
||
Net Weight(kg) |
19.5 |
23.5 |
28.0 |